Gas Detection for Breweries and Drinks Production: A Practical UK Guide
Breweries, cider makers, distilleries, soft drinks plants and bar cellars share one gas hazard that is easy to overlook because it is part of the product: carbon dioxide. It is produced in large volumes during fermentation, stored in cylinders and bulk tanks for carbonation and dispense, and gives no reliable warning by sight or smell. This guide covers the hazards, which gas monitor fits each job, and how to use and look after it.
The gas hazards in breweries and drinks production
CO2 is the main concern, but rarely the only one. A site risk assessment will typically look at:
CO2 from fermentation. An active fermenting vessel releases a steady stream of gas unless it is captured or vented outside.
CO2 from cylinders and bulk storage. Leaking regulators, couplings and beer lines in cellars, keg stores and carbonation areas can release gas continuously.
Oxygen depletion from nitrogen or mixed gas used for dispense and purging, or from large CO2 releases.
Confined spaces. Fermenters, conditioning tanks, mash tuns, silos and pits can hold CO2 long after emptying.
Flammable ethanol vapour in distilleries and spirits stores.
Ammonia on larger sites with ammonia refrigeration.
Carbon monoxide from forklifts or other fuel-burning equipment indoors.
CO2 is heavier than air, so it collects in cellars, pits, drains and the bottom of tanks, and can stay there in still air. A space that seems normal at the top of the stairs can be very different at floor level. At high concentrations CO2 can cause headaches, breathlessness and loss of consciousness.
CO2 exposure limits and the oxygen trap
CO2 has a UK workplace exposure limit (WEL) in HSE's EH40/2005 (fourth edition, January 2020) of 5,000 ppm (0.5%) as an 8-hour time-weighted average and 15,000 ppm (1.5%) as a 15-minute short-term limit. WELs are legally binding where they apply under COSHH, but they are only one part of COSHH control: you still need to prevent or control exposure as far as you can. See our EH40 reference guide for the limits of other common gases.
The trap many sites fall into: an oxygen sensor will not warn you about CO2 at these levels. Normal air is about 20.9% oxygen, and adding 1.5% CO2 lowers that by only around 0.3%, nowhere near a typical low-oxygen alarm. A standard 4-gas monitor (oxygen, flammable, carbon monoxide and hydrogen sulphide) does not measure CO2 at all. If CO2 is your hazard, you need a monitor with a CO2 sensor, usually infrared.
Which gas monitor fits which job
Match the instrument to the task:
Single gas CO2 monitors. A personal CO2 monitor is the simplest way to cover routine work in cellars, keg stores and fermentation rooms. Browse our single gas monitors.
Multigas monitors. For entry into tanks, vessels and pits, a multigas instrument with CO2, oxygen and flammable sensors (plus other toxic sensors where the risk assessment calls for them) gives a fuller picture. A pumped model with a probe lets you test the bottom of a vessel before anyone goes in.
Fixed gas detection. Cellars, fermentation halls and gas storage areas often benefit from fixed CO2 and oxygen detectors with a warning beacon outside the entrance. We supply fixed systems to your specification and service them.
Day-to-day use: start-up, bump test and wearing position
Start up in clean air. Switch on in fresh air, away from fermenters and gas storage, and let the self-test and warm-up finish.
Bump test. Many manufacturers recommend a bump test before each day's use, exposing the sensors to test gas to prove they respond and the alarms work. If it fails, take the monitor out of use.
Wear it in the breathing zone. Clip a personal monitor to the collar or chest, close to the nose and mouth, not on a belt or in a pocket.
Sample low before you go low. Because CO2 sinks, test at floor level with a pumped instrument before entry, not just at the hatch.
Keep it on and worn for the whole time in the area.
Alarm settings and what to do on alarm
EH40 does not set alarm levels. Alarm settings follow your risk assessment, your site or company standard, the purpose of the monitoring and what the instrument can do. An instantaneous alarm does not measure an 8-hour or 15-minute average, so setting an alarm at a WEL does not by itself show compliance. For oxygen, 19.5% (low) and 23.5% (high) are typical settings, and for flammable gas 10% and 20% of the lower explosive limit (LEL) are typical, but both depend on the site standard and risk assessment.
When a monitor alarms:
Stop work and leave the area at once, by the agreed route, into fresh air.
Warn others nearby and stop anyone else going in.
Do not go back in to rescue someone unless you are trained, equipped and following the site's rescue plan.
Report the alarm and find the cause, such as a leaking coupling or failed extraction, before anyone re-enters.
Confined space entry into tanks and vessels
Fermenters and conditioning tanks are classic confined spaces under the Confined Spaces Regulations 1997. Avoid entry where you can, for example with cleaning-in-place and external inspection. Where entry is unavoidable you need a safe system of work: isolation, ventilation, pre-entry gas testing from outside, continuous monitoring and emergency arrangements in place before work starts. Distilleries handling ethanol should also consider DSEAR.
Calibration and record keeping
Calibration intervals vary by instrument and use; follow the manufacturer, and six months is common. Keep a record for each instrument: serial number, dated bump test results, calibration certificates and any repairs. These records help show equipment is maintained as part of your COSHH and confined space controls.
Our engineers calibrate and repair most makes, including Crowcon, Honeywell, WatchGas, Dräger, MSA, Industrial Scientific, GMI and Oldham, with traceable calibration. Calibration of any single gas monitor is £40 and any multigas monitor is £90 (ex VAT). Find out more about our service and calibration. For a busy season, a tank entry or cover while your instruments are away, gas detector hire starts at £35 per week for a single gas monitor and £85 per week for a multigas monitor (ex VAT).
Training your team
Many gas monitor problems come down to use: bump tests skipped or alarms not understood. Our gas detection training covers hazards, monitor use, bump testing and responding to alarms. On-site training is £750 per day anywhere in the UK, or £350 for a 3-hour online session (ex VAT).
Frequently asked questions
Will an oxygen monitor warn me about CO2?
Not reliably. CO2 can reach its WEL while the oxygen reading has barely changed, so you need a monitor with a dedicated CO2 sensor.
Do bar and pub cellars need CO2 monitoring?
Cellars with CO2 or mixed gas cylinders are a common place for leaks to build up, so your risk assessment should consider them. A common approach is fixed CO2 and oxygen detection with a beacon at the cellar door, plus personal monitors for staff changing cylinders.
How often should a CO2 monitor be calibrated?
Follow the manufacturer's guidance; six months is a common interval. Many manufacturers also recommend a bump test before each day's use.
Talk to 7 Solutions
For help choosing CO2 detection, arranging hire, calibration or training for your brewery or drinks site, call 7 Solutions on 01489 326031 or email sales@7solutions.co.uk.